Shopping List
Shopping List
SGD - S$
Image
/
/
/
/
Schneider Electric VZ12 Additional Neutral Block,tesys Control,80A,for V3 / V4
Schneider Electric VZ12 Additional Neutral Block,tesys Control,80A,for V3 / V4
Image
Image
Specifications
infotip-icon
View other Auxiliary Contact dimensions or variations
Please select at least one specification below.
Range
TeSys
Standard
IEC 60947-3
IP Degree of Protection
IP20 conforming to IEC 60529
Ambient Air Temperature for Operation
-20…50 °C
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz
Width
20 mm
This spec is not available in the specification table.
Device Short Name
VZ
This spec is not available in the specification table.
Product or Component Type
Additional neutral block
This spec is not available in the specification table.
Depth
46 mm
This spec is not available in the specification table.
Poles Description
1N
This spec is not available in the specification table.
[Uimp] Rated Impulse Withstand Voltage
6 kV
This spec is not available in the specification table.
Connections - Terminals
Screw clamp terminals16 mm² - flexible - with cable end Screw clamp terminals25 mm² - solid
This spec is not available in the specification table.
Product certifications
GL UL CSA UKCA
This spec is not available in the specification table.
Height
83 mm
This spec is not available in the specification table.
Mechanical Durability
30000 cycles
This spec is not available in the specification table.
Electrical Durability
30000 cycles DC-1...5 30000 cycles AC-21
This spec is not available in the specification table.
Tightening Torque
4 N.m - on screw clamp terminals
This spec is not available in the specification table.
[Ith] conventional free air thermal current
80 A
This spec is not available in the specification table.
Fire resistance
960 °C conforming to IEC 60695-2-1
This spec is not available in the specification table.
Mechanical robustness
Vibrations 10...150 Hz (1 gn) conforming to IEC 60068-2-6 Shocks 11 ms (15 gn) conforming to IEC 60068-2-27
This spec is not available in the specification table.
Range compatibility
TeSys TeSys VARIO switch disconnector
This spec is not available in the specification table.
Product Compatibility
V3 V4
This spec is not available in the specification table.
Mounting location
Left Right
This spec is not available in the specification table.
Contacts operation
Early make, late break
This spec is not available in the specification table.
Performance level
High performance
This spec is not available in the specification table.
Network Type
AC DC
This spec is not available in the specification table.
Network Frequency
50/60 Hz
This spec is not available in the specification table.
Contacts type and composition
1 NO
This spec is not available in the specification table.
Product Description
S$ 69.50
(exc. GST)
S$ 75.76
(inc. GST)
Quantity:
/ EA
This item is sold by
Image
Schneider Electric
Shop by Specification Table
You can find items with similar specifications from the table below.
Auxiliary Contact
58 Items
auxiliary-contact-img
Rated Current
5 A <= 690 V AC-12 conforming to IEC 60947-5-1 5 A <= 48 V AC-15 conforming to IEC 60947-5-1 4 A 110/127 V AC-15 conforming to IEC 60947-5-1 3 A 220/240 V AC-15 conforming to IEC 60947-5-1 2.5 A 380...440 V AC-15 conforming to IEC 60947-5-1 0.11 A 660/690 V AC-15 conforming to IEC 60947-5-1 5 A <= 24 V DC-12 conforming to IEC 60947-5-1 2.5 A 48 V DC-12 conforming to IEC 60947-5-1 0.6 A 110/127 V DC-12 conforming to IEC 60947-5-1 0.3 A 250 V DC-12 conforming to IEC 60947-5-1 2.5 A <= 24 V DC-12 conforming to IEC 60947-5-1 1.2 A 48 V DC-12 conforming to IEC 60947-5-1 0.35 A 110/127 V DC-12 conforming to IEC 60947-5-1 0.05 A 250 V DC-12 conforming to IEC 60947-5-1 1 A <= 24 V DC-12 conforming to IEC 60947-5-1 0.2 A 48 V DC-12 conforming to IEC 60947-5-1 0.05 A 110/127 V DC-12 conforming to IEC 60947-5-1 0.03 A 250 V DC-12 conforming to IEC 60947-5-1, 6 A at 120 V AC-15 1.04 A at 690 V AC-15 0.55 A at 125 V DC-13 0.1 A at 600 V DC-13, 6 A at 120 V AC-15 3 A at 240 V AC-15 1.8 A at 400 V AC-15 1.5 A at 480 V AC-15 2.8 A at 24 V DC-13 1.4 A at 48 V DC-13 0.55 A at 125 V DC-13 0.27 A at 250 V DC-13 0.15 A at 400 V DC-13, AC-12: 3 A at 250 V AC 50/60 Hz AC-12: 5 A at 125 V AC 50/60 Hz AC-12: 5 A at 24 V AC 50/60 Hz AC-12: 5 A at 48 V AC 50/60 Hz AC-15: 2 A at 250 V AC 50/60 Hz AC-15: 3 A at 125 V AC 50/60 Hz AC-15: 5 A at 24 V AC 50/60 Hz AC-15: 5 A at 48 V AC 50/60 Hz DC-12: 0.2 A at 250 V DC DC-12: 0.4 A at 125 V DC DC-12: 2.5 A at 48 V DC DC-12: 4 A at 24 V DC DC-14: 0.2 A at 250 V DC DC-14: 0.4 A at 125 V DC DC-14: 1 A at 48 V DC DC-14: 3 A at 24 V DC
Colour
Dark grey, White
Range
Acti9, Acti 9, C6-, Compact
Standard
CSA C22.2 No 60947-5-1 EN/IEC 60947-5-1 UL 60947-5-1, EN/IEC 60947-5-1, EN/IEC 60947-5-1 GB/T 14048.5, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1
[Ui] Rated Insulation Voltage
250 V conforming to CSA 250 V conforming to IEC 60947-5-1 250 V conforming to UL, 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 250 V conforming to IEC 60947-1, 400 V, 500 V
IP Degree of Protection
IP20 conforming to EN/IEC 60947-5-1, IP20 conforming to IEC 60529, IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529, IP2X
Ambient Air Temperature for Operation
-20…50 °C, -25…50 °C, -25…60 °C, -35…70 °C
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Auxiliary Contact from SCHNEIDER ELECTRIC
Source & compare similar products
More from Auxiliary Contact
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top