This Harmony XPER311 is a single foot switch. Its degree of protection is IP66. It has a cover, metallic material, orange color, 2 NC + 2 NO. It is part of the range Harmony XPE foot switches - Control and signaling units for safety applications.
- Range of product: Harmony XPE
- Product or component type: Foot switch
- Material: Metal
- Foot switch type: Single foot switch
- Device short name: XPER
- Provided equipment: Cover
- Trigger mechanism: Without trigger mechanism
- Contact operation: 1 step
- Contacts type and composition: 2 NC + NO
- Colour: Orange
- Positive opening: With, conforming to EN/IEC 60947-5-1 appendix K
- Connections - terminals:
- Screw clamp terminal, <= 1 x 2.5 mm² with or without cable end
- Screw clamp terminal, <= 2 x 1.5 mm² with or without cable end
- Cable entry: 2 entries tapped for Pg 16 cable gland
- Mechanical durability: 15,000,000 cycles
- Rated operational current (Ie):
- 3 A, 240 V, AC-15, A300
- 0.27 A, 250 V, DC-13, Q300, conforming to EN/IEC 60947-5-1 appendix A
- Rated insulation voltage (Ui):
- 500 V (pollution degree 3), conforming to EN/IEC 60947-1
- 500 V (pollution degree 3), conforming to NF C 20-040 group C
- 500 V (pollution degree 3), conforming to VDE 0110 group C
- 300 V, conforming to UL 508
- 300 V, conforming to CSA C22.2 No 14
- Rated impulse withstand voltage (Uimp): 6 kV, conforming to EN/IEC 60947-1
- Maximum resistance across terminals: 25 MOhm, conforming to IEC 60255-7 category 3, NF C 93-050 method A
- Short-circuit protection: 10 A cartridge fuse type gG, conforming to EN/IEC 60947-5-1, VDE 0660-200
- Rated operational power in W:
- 10 W DC-13, operating rate <60 cyc/mn, 5,000,000 cycles, 24 V, load factor: 0.5, conforming to EN/IEC 60947-5-1 appendix C
- 4 W DC-13, operating rate <60 cyc/mn, 5,000,000 cycles, 120 V, load factor: 0.5, conforming to EN/IEC 60947-5-1 appendix C
- 7 W DC-13, operating rate <60 cyc/mn, 5,000,000 cycles, 48 V, load factor: 0.5, conforming to EN/IEC 60947-5-1 appendix C
- Net weight: 2.42 kg
- Standards:
- Product certifications:
- Protective treatment: TC
- Ambient air temperature:
- For operation: -25…70 °C
- For storage: -40…70 °C
- Vibration resistance: 15 gn (f= 10…500 Hz), conforming to IEC 60068-2-6
- Shock resistance:
- 150 gn, conforming to NF E 09-031
- 20 gn, conforming to IEC 60068-2-27
- Overvoltage category:
- Class I, conforming to EN/IEC 61140
- Class I, conforming to NF C 20-030
- IP degree of protection:
- IP66, conforming to IEC 60529
- IP669, conforming to NF C 20-010